Tel: +86-134-31394972
E-mail: sales@pre-webguidesystem.com
After the photoelectric detection head, motor, limit switch and power supply connection of the photoelectric correction sensor guide system are accurate, the operation can be carried out as follows:
1. Turn on the power switch, and the bias indicator will start flashing for three seconds in a disciplined manner, and the buzzer will sound three times; then the state of the controller before the previous shutdown.
2. If the tape is first adjusted, switch to manual mode. Press the “→←” button to make the motor move, aim the light point of the photoelectric head to the edge of the tracked edge or line; and adjust the acuity of the photoelectric head so that the indicator light has obvious bright and dark changes in the color code.
3. Then you can run under the “automatic” method, at which point the movement of the material is too fine. If it is only moving towards one direction (the normal environment should be alternately moving in the horizontal direction), you need to press the polarity button to change in time.
4. Others can decide the operation of the key when the automatic method is made, so that the motor and the thing are at the matching frequency. For example, in a single photoelectric method, the speed should be increased when the speed is fast.
5. If a very-limit action is generated, the buzzer will alarm and the motor will stop running immediately. Through the introduction of the above matters concerning the operation of the photoelectric guide sensor guide system, I believe that you have a deeper understanding of the photoelectric guide sensor!
Previous: What Are The Main Maintenance Work Of The Guide Of The Photoelectric Guide?
Next: What Is The Working Principle Of The Thermopile Sensor In The Hot Metal Detector Component?