banner

Operation Steps Of Photoelectric Automatic Guide System

- Sep 24, 2019-

When the photoelectric detector, motor, limit switch and power supply are all accurate, you can follow the steps below:
1. Turn on the power switch, and the bias indicator will begin to flash for three seconds in a disciplined manner, and the buzzer will sound three times;

Then the controller goes to the state before the shutdown. 2. If the tape is first adjusted, switch to the "Manual" state. Press “→” “←”, key to make the motor move, aim the light spot of the photoelectric head to the edge of the tracked edge or line; and adjust the acuity of the photoelectric head so that the indicator light is brightly visible in the color code. Dark change.

3. Then you can run under the “automatic” method, at which point the movement of the material is too fine. If it is only moving towards one direction (the normal environment should be alternately moving in the horizontal direction), press the “Polarity” button to change in time.

4. In addition, in the "automatic" method, you can decide the operation of the "+" and "-" keys to make the motor and things match. For example, in a single photoelectric method, the speed should be increased when the speed is fast.

5. If a very-limit action is generated, the buzzer will alarm and the motor will stop running immediately. Too fine events 1. The placement of this product should be able to avoid high voltage and strong magnetic fields.

2. The controller should be used as much as possible in a place with steam and corrosive gases. 3. The casing should be connected to the shelter. 4. The lens connecting the photo head is neat and tidy. 5. When the external ambient temperature is too high, please close the temperature rise of the fine motor and controller.